Outages

How do I reset a well pump after a power outage?

Answered October 20, 2026.

Most pumps restart on their own. If yours did not, work the circuit in this order and stop at whatever fixes it.

The pump’s own breaker, not the main. Switch it fully off, then back on. A surge as the grid dropped can trip it mid-cycle.

The pressure switch. A switch with a low pressure cut-off latches off when pressure drops far enough below its cut-in setting, which is what a drained tank does. The lever is spring loaded, so you hold it at Start until the gauge climbs past the cut-off, then let it go to Auto. Nothing resets it for you.

The overload in the control box. On a three-wire submersible, Red Lion’s guide says to check voltage at the fuse box, then at the pressure switch terminals, then push the red overload reset buttons on the bottom of the control center.

Stop and call a licensed well contractor if the breaker trips a second time, if the motor hums without starting, or if the pump runs but no water arrives. Those are motor, wiring or water level faults, and resetting past them burns out a motor.

Two hard rules. Never open the well cap or touch pump wiring with the circuit live. CDC warns that electrical shock can occur if you try repairs without experience, and says a qualified electrician or well contractor should check the wiring before power goes back to the well. Control box capacitors hold a charge after the power is off.

And if the wellhead or control box was underwater, Virginia’s health department says do not turn the pump on until the electrical system is completely dry. Count what you have while you wait, the way you would in the first hour of any water outage.

All water emergency questions